Konrad Klimaszewski (NCBJ), Wojciech Krzemien (NCBJ)

Participants:

Michal Mazurek(MM)
Wojciech Krzemień (WK)
Konrad Klimaszewski (KK)
Roman Shopa (RS)
Lech Raczynski (LR)
Mateusz Bała (MB)
Maciej Zajkowski (MZ)


Questions/Remarks:

WK: mu depends not only on the polarisation measurement's detector efficiency but also on the type of correlations.

KK: Question about deltaX and deltaY in Parashi measurement.  Are the detector matrices oriented perpendicular to the photon direction?
MB: They are. However, they neglect the depth (along the incoming photon direction), so the phi angle is reconstructed based on X and Y. In addition, the Compton scattering angles in the detector are around 90 degrees.

KK: Can you simulate the multiple scattering in the detector in your model?
M.B/W.K: In principle yes, but we have a limitation to the number of consecutive scatterings in our implementation now.